A successful pregnancy outcome in a patient with cardiac permanent pacemaker

Authors

  • Niranjana Rajan Department of Obstetrics and Gynaecology, Vijaya Medical and Educational Trust, Vadapalani, Chennai, Tamil Nadu, India
  • Ramayee Ramanathan DNB Obstetrics and Gynaecology, Vijaya Medical and Educational Trust, Vadapalani, Chennai, Tamil Nadu, India
  • Vijayakumar Manam Department of Cardiology, Vijaya Heart Foundation, Vadapalani, Chennai, Tamil Nadu, India

DOI:

https://doi.org/10.18203/2320-1770.ijrcog20250210

Keywords:

Complete heart block, Permanent pacemaker in pregnancy, Cardiac patient

Abstract

We present a case of 31 years old Gravida 2 Abortion 1 at 25 weeks of gestation with history of congenital heart disease- Left aorto-ventricular tunnel, for which she had intracardiac repair at 7 years of age. She had bradycardia, syncopal attacks, diagnosed as complete heart block at 26 yrs of age and had permanent pacemaker implantation had come for antenatal care. Echocardiogram showed ejection fraction of 30%, global hypokinesia of left ventricle and moderate aortic regurgitation. Patient was asymptomatic. As per cardiologist opinion, started on Tab. Amiodarone 100mg once daily on alternate days and pregnancy continued. Patient was admitted at 38wks, for elective lower segment caesarean section, in view of cardiac condition, pacemaker adjustment done before anaesthesia. Under general anaesthesia, delivered an alive boy baby of birth weight 3.2 kg with a good Apgar score. Intraoperative and postoperative period was uneventful. At postoperative follow-up, patient was asymptomatic. Hence, we report a successful pregnancy outcome despite critical ejection fraction in a pregnant patient with permanent pacemaker.

 

Metrics

Metrics Loading ...

References

Grover S, Sheth P, Haines DE, Khan M, Gonik B. Management of cardiac pacemakers in a pregnant patient. Open J Obste Gynecol. 2014;5(01):60. DOI: https://doi.org/10.4236/ojog.2015.51009

Hall GA Textbook of Medical Physiology. 11th Edition, Saunders, Philadelphia. 2005.

Clapp III JF, Capeless E. Cardiovascular function before, during, and after the first and subsequent pregnancies. The Am J Cardiol. 1997;80(11):1469-73. DOI: https://doi.org/10.1016/S0002-9149(97)00738-8

Toogood G. Pacemaker therapies in cardiology. Austra Fam Phys. 2007;36(7):518-9.

Benrey J. Indications and choices in pacemaker therapy. Texas Heart Institute J. 1991;18(3):170.

Beckman CRB, Ling FW, Barzansky BM, Herbert NP, Laube DW and Smith RP. Obstetrics and Gynecology. 6th Edition, Lippincott Williams and Wilkins, Philadelphia. 2010.

Kurjak, A, Chervenak, FA Eds. Textbook of Perinatal Medicine. 2nd Ed. CRC Press, Boca Raton; 2010: 2304.

Simpson J. Anesthesia and the Patient with Co-Existing Heart Disease. Little Brown & Co, Boston. 1993: 474.

Zakowski MI, Ramanathan S. Uteroplacental circulation and Respiratory gas exchange. Shnider and Levinson's Anesthesia for Obstetrics. 2012;10:18.

Matorras R, Diez J, Saez M, Montoya F, Aranguren G, Rodriguez-Escudero FJ. Repeat pregnancy associated with cardiac pacemaker. Int J Gynecol Obst. 1991;36(4):323-7. DOI: https://doi.org/10.1016/0020-7292(91)90487-P

Batra YK, Bali IM. Effect of coagulating and cutting current on a demand pacemaker during transurethral resection of the prostate. A case report. Canadian Anaes Soc J. 1978;25:65-6. DOI: https://doi.org/10.1007/BF03006788

Mangar D, Atlas GM, Kane PB. Electrocautery-induced pacemaker malfunction during surgery. Canadian J Anaes. 1991;38:616-8. DOI: https://doi.org/10.1007/BF03008198

Downloads

Published

2025-01-29

How to Cite

Rajan, N., Ramanathan, R., & Manam, V. (2025). A successful pregnancy outcome in a patient with cardiac permanent pacemaker. International Journal of Reproduction, Contraception, Obstetrics and Gynecology, 14(2), 645–648. https://doi.org/10.18203/2320-1770.ijrcog20250210

Issue

Section

Case Reports