Prediction of preterm labor using ultrasound measurement of cervical length at 11 to 14 weeks and 18 to 20 weeks

Authors

  • Laxman Kumar Department of Obstetrics and Gynaecology, Pacific Institute of Medical Science, Udaipur, Rajasthan, India
  • Chand Ughareja Department of Obstetrics and Gynaecology, Pacific Institute of Medical Science, Udaipur, Rajasthan, India
  • Darshit Tailor Department of Obstetrics and Gynaecology, Pacific Institute of Medical Science, Udaipur, Rajasthan, India

DOI:

https://doi.org/10.18203/2320-1770.ijrcog20251428

Keywords:

Preterm birth, Ultrasonography, Cervical length

Abstract

Background: Preterm birth (PTB) is the most important problems that pose dilemmas for both the obstetrician and neonatologist, as it is the leading cause of perinatal morbidity and mortality around the world. Routine cervical length screening during early pregnancy can predict PTB. Objectives were to predict the PTB with the use of ultrasonographic cervical length measurement at 11-14 weeks and 18-20 weeks of gestation.

Methods: This prospective observational study was conducted from 1st March 2024 till 31st March 2024 at department of obstetrics and gynaecology pacific institute of medical science Udaipur. Total 100 cases selected which are routinely advised for ultrasound during antenatal checkup at 11-14 weeks and 18-20 weeks. In this study all the analysis was performed using 10.0 version of statistical software SPSS.

Results: In this study most women (49.0%) belonged to the age group of 26-30 years. 78.0% of women had term births and 22.0% of women had PTBs. It was observed that 12 women had cervical length <25 mm at 18-20 weeks and 83% of them had PTBs while 16.6% had term birth.

Conclusions: Ultrasound measurement of cervical length in early pregnancy is a reliable and cost-effective method for screening of PTB. We observed that women with shorter cervix early on in pregnancy had a greater number of PTB s as compared to women with normal length of cervix.

Metrics

Metrics Loading ...

References

Berghella V, Saccone G. Cervical assessment by ultrasound for preventing preterm delivery. Cochrane Database Syst Rev. 2019;9(9):CD007235. DOI: https://doi.org/10.1002/14651858.CD007235.pub4

World Health Organization Fact Sheet #363. 2014. Available at: http://www.who.int/mediacentre/factsheets/fs363/en/. Accessed on 16 March 2025.

Kiss H, Petricevic L, Husslein P. Prospective randomised controlled trial of an infection screening programme to reduce the rate of preterm delivery. BMJ. 2004;329(7462):371. DOI: https://doi.org/10.1136/bmj.38169.519653.EB

McGregor JA, French JI. Pathogenesis to treatment: preventing preterm birth mediated by infection. Infect Dis Obstet Gynecol. 1997;5(2):106-14. DOI: https://doi.org/10.1155/S1064744997000173

Mateus J, Pereira L, Baxter J, Berghella V, Tolosa J. Effectiveness of fetal fibronectin testing compared with digital cervical assessment of women with preterm contractions. Am J Perinatol. 2007;24(6):381-5. DOI: https://doi.org/10.1055/s-2007-981849

Reiter E, Nielsen KA, Fedder J. Digital examination and transvaginal scan-competing or complementary for predicting preterm birth? Acta Obstet Gynecol Scand. 2012;91(4):428-38. DOI: https://doi.org/10.1111/j.1600-0412.2011.01341.x

Crane JM, Van den Hof M, Armson BA, Liston R. Transvaginal ultrasound in the prediction of preterm delivery: singleton and twin gestations. Obstet Gynecol. 1997;90(3):357-63. DOI: https://doi.org/10.1016/S0029-7844(97)00277-9

Andersen HF. Use of fetal fibronectin in women at risk for preterm delivery. Clin Obstet Gynecol. 2000;43(4):746-58. DOI: https://doi.org/10.1097/00003081-200012000-00005

Kashanian M, Bahasadri S, Ghasemi A, Bathaee S. Value of serum urocortin concentration in the prediction of preterm birth. J Obstet Gynaecol Res. 2013;39:26-30. DOI: https://doi.org/10.1111/j.1447-0756.2012.01887.x

Preterm birth. Available at: https://www.who.int/ news-room/fact-sheets/detail/preterm-birth. Accessed on 27 April 2025.

Werner EF, Hamel MS, Orzechowski K, Berghella V, Thung SF. Cost-effectiveness of transvaginal ultrasound cervical length screening in singletons without a prior preterm birth: an update. Am J Obstet Gynecol. 2015;213(4):554.e1-6. DOI: https://doi.org/10.1016/j.ajog.2015.06.020

Berghella V, Bega G, Tolosa JE, Berghella M. Ultrasound assessment of the cervix. Clin Obstet Gynecol. 2003;46(4):947-62. DOI: https://doi.org/10.1097/00003081-200312000-00026

Hassan SS, Romero R, Berry SM, Dang K, Blackwell SC, Treadwell MC, et al. Patients with an ultrasonographic cervical length < or =15 mm has nearly a 50% risk of early spontaneous preterm delivery. Am J Obstet Gynecol. 2000;182(6):1458-67. DOI: https://doi.org/10.1067/mob.2000.106851

Committee on Practice Bulletins-Obstetrics, The American College of Obstetricians and Gynaecologists. Practice bulletin no. 130: prediction and prevention of preterm birth. Obstet Gynecol. 2012;120(4):964-73. DOI: https://doi.org/10.1097/AOG.0b013e3182723b1b

Daniel WW, Cross CL. Biostatistics: A foundation for analysis in the health sciences. 10th ed. New York: John Wiley and Sons. 2013.

Jana A. Correlates of low birth weight and preterm birth in India. PLoS One. 2023;18(8):e0287919. DOI: https://doi.org/10.1371/journal.pone.0287919

Wadhawan UT, Shah NP, Patil AN. Prediction of preterm labour by cervical length. Int J Reprod Contracept Obstet Gynecol. 2017;6(7):2978-82. DOI: https://doi.org/10.18203/2320-1770.ijrcog20172920

Kore SJ. Prediction of risk of preterm delivery by cervical assessment by transvaginal ultrasonography. Group. 2009;28:28-32.

Raval BM, Sisodiya VP, Yadava PA, Mehta ST, Patel SR, Dadhania BH. Measurement of cervical length using transvaginal sonography for prediction of preterm labour. Int J Reprod Contracept Obstet Gynecol. 2020;9(11):4471-6. DOI: https://doi.org/10.18203/2320-1770.ijrcog20204795

Priyadarshani P, Kaur G. Predicting preterm labour by cervical length measurement. Int J Reprod Contracept Obstet Gynecol. 2017;5(6):1809-13. DOI: https://doi.org/10.18203/2320-1770.ijrcog20161667

Ho N, Liu C, Nguyen A, Lehner C, Amoako A, Sekar R. Prediction of time of delivery using cervical length measurement in women with threatened preterm labor. J Matern Fetal Neonatal Med. 2021;34(16):2649-54. DOI: https://doi.org/10.1080/14767058.2019.1670798

Hebbar S, Samjhana K. Role of mid-trimester transvaginal cervical ultrasound in prediction of preterm delivery. Med J Malaysia. 2006;61(3):307-11.

Downloads

Published

2025-05-08

How to Cite

Kumar, L., Ughareja, C., & Tailor, D. (2025). Prediction of preterm labor using ultrasound measurement of cervical length at 11 to 14 weeks and 18 to 20 weeks. International Journal of Reproduction, Contraception, Obstetrics and Gynecology. https://doi.org/10.18203/2320-1770.ijrcog20251428

Issue

Section

Original Research Articles