Correlation of optic nerve sheath diameter in raised intracranial pressure in pre-eclampsia: a prospective observational study in preeclampsia in a low resource setting
DOI:
https://doi.org/10.18203/2320-1770.ijrcog20264405Keywords:
Fundus examination, Optic nerve sheath diameter, Pre-eclampsia, Raised intracranial pressure, Optic ultrasonographyAbstract
Background: The study aimed to measure and compare optic nerve sheath diameter (ONSD) among women diagnosed with pre-eclampsia and normotensive pregnant controls.
Methods: A total of 120 patients were enrolled in this prospective study and assigned to two groups. There were 61 patients in the group A (Pre-eclampsia group) and 59 in group B (normotensive). Outcome was evaluated using Optic nerve sheath diameter measurements and to see whether there was statistically significant difference in both the groups. Sensitivity for the diagnostic test was measured in comparison to standard method of fundoscopy.
Results: The baseline demographics in the two groups were comparable. Mean Optic nerve sheath diameter was significantly higher in Group A indicating high intracranial pressure in women with pre-eclampsia. There was significant reduction in mean Optic nerve sheath diameter post treatment in Group A(p<0.001). Similarly, the sensitivity of fundoscopy as compared to ONSD measurement to detect raised intracranial pressure was found to be just 10%.
Conclusion: The results of the study suggest that measurement of ONSD is a bedside, minimally invasive procedure and avoids radiation exposure. It is particularly suitable in pregnancy, where imaging modalities such as CT or MRI may be limited due to logistical constraints or delayed access. Additionally, optic nerve ultrasonography can be repeated frequently for monitoring changes in intracranial pressure over time, making it valuable in dynamic clinical decision-making.
References
American College of Obstetricians and Gynecologists. Gestational hypertension and preeclampsia: ACOG Practice Bulletin, Number 222. Obstet Gynecol. 2020;135(6):e237–60.
Mol BWJ, Roberts CT, Thangaratinam S, Magee LA, de Groot CJM, Hofmeyr GJ. Pre-eclampsia. Lancet. 2016;387(10022):999–1011.
Steegers EA, von Dadelszen P, Duvekot JJ, Pijnenborg R. Pre-eclampsia. Lancet. 2010;376(9741):631–44.
Rana S, Lemoine E, Granger JP, Karumanchi SA. Preeclampsia: pathophysiology, challenges, and perspectives. Circ Res. 2019;124(7):1094–112.
Hansen WF, Burnham SJ, Svendsen TO, Katz VL, Thorp JM Jr, Hansen AR. Transcranial Doppler findings of cerebral vasospasm in preeclampsia. J Matern Fetal Med. 1996;5(4):194–200.
Dubost C, Le Gouez A, Jouffroy V, et al. Optic nerve sheath diameter used as ultrasonographic assessment of the incidence of raised intracranial pressure in preeclampsia: a pilot study. Anesthesiology. 2012;116(5):1066–71.
El-Zoghby I, Fathy I, Atta F, Elhadidy SET. Ultrasonographic measurement of optic nerve sheath diameter as a predictor of severity of preeclampsia: a cross-sectional analytic study. Res Opin Anesth Intensive Care. 2025;12(2):126–32.
Singh SK, Bhatia K. Ultrasonographic optic nerve sheath diameter as a surrogate measure of raised intracranial pressure in severe pregnancy-induced hypertension patients. Anesth Essays Res. 2018;12(1):42–6.
Jan S, Nazir O, Hussain A, Kumar A. Comparison of optic nerve sheath diameter in preeclampsia and normal pregnancy using ocular USG. Int J Reprod Contracept Obstet Gynecol. 2022;11(7):1896–9.
Jha AK, Sah BK, Jha S. Measurement of optic nerve sheath diameter using ultrasound as an indicator of raised intracranial pressure in patients with pre-eclampsia. Nepal J Radiol. 2025;14(2):9–15.
Arzpeyma SF, Khorram PB, Asgharnia M, Mohtasham-Amiri Z. Investigating the relationship between ultrasound measured optic nerve sheath diameter and preeclampsia. AIMS Med Sci. 2019;6(3):250–9.
Mota MF da, Amorim MM de, Correia MDT, Katz L. The optic nerve sheath in hypertensive disorders of pregnancy and perinatal outcomes: a cohort study. BMC Pregnancy Childbirth. 2024;24(1):654.
González MC, Rodríguez DC, Alvarez MM, Wong LY, Escobedo LR, Roibal RS. Daily optic nerve sheath diameter monitoring for early detection of cerebral edema in preeclampsia and eclampsia. BioNatura J. 2025;2(4):13.
Rani K, Jain P, Bhogawar SD, Bhogawar RS, Prasad MK, Choudhary AK. Ultrasonographic changes in transorbital measurement of optic nerve sheath diameter in magnesium sulfate-treated severely preeclamptic patients. Anesth Essays Res. 2022;16(3):366–72.
Biswas J, Khatun N, Bandyopadhyay R, Bhattacharya N, Maitra A, Mukherjee S, et al. Optic nerve sheath diameter measurements using ultrasonography to diagnose raised intracranial pressure in preeclampsia: an observational study. J Turk Ger Gynecol Assoc. 2023;24(1):5–11.
Wilson CL, Leaman SM, O’Brien C, Savage D, Hart L, Jehle D. Novice emergency physician ultrasonography of optic nerve sheath diameter compared to ophthalmologist fundoscopic evaluation for papilledema. J Am Coll Emerg Physicians Open. 2021;2(1):e12355.
Hemanth VS, Sethu Babu, Mithun Murali. Utility of optic nerve sheath diameter measurement by point-of-care ultrasound to detect raised intracranial pressure: a prospective observational study. J Res Med Dent Sci. 2022;10(7):66–71.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Aashima Sharma, Nidhi Jindal, Rama Thakur, Rohit Bhoil

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.