Study on the acceptance, complications and continuation rate of post-partum family planning using the post placental intrauterine contraceptive device among women delivering at a tertiary care hospital
Keywords:
Acceptance, Complications, Post placental intrauterine contraceptiveAbstract
Background: Post placental intrauterine contraceptive device use in India showed that most women were satisfied with their choice of immediate insertion of an IUCD and the rates of complications were relatively low. The large proportion of women accepting the method to limit future childbearing indicates the important place post placental IUCD hold. This study was done to evaluate the acceptance of intrauterine contraceptive device as an immediate family planning method following delivery. The complications associated with it were identified and continuation rates were assessed.
Methods: Women admitted for delivery in a tertiary care hospital were included in the study. Only women who fulfilled the medical eligibility criteria were included in the study.
Results: A total of 4209 women were counseled of which 780 (18.5%) women accepted the method, 3429 declined. Out of the 780 cases, 764 came for follow up, and 16 were lost to follow up, spontaneous expulsion was seen in 2 (0.2%) cases, removal was done on request in 1 case and continuation was seen in 761 (97.56%) women.
Conclusions: The Post placental intrauterine contraceptive device is safe to insert immediately after delivery. It has good acceptance with minimal expulsion and very high continuation rates.References
Chi IC, Wilkens L, Rogers S. Expulsions in immediate postpartum insertions of Lippes Loop D and Copper T IUDs and their counterpart Delta devices: an epidemiological analysis. Contraception. 1985;32:119-34.
Tatum HJ, Beltran RS, Ramos R, Van Kets H, Sivin I, Schmidt FH. Immediate postplacental insertion of GYNE-T 380 and GYNE-T 380 postpartum intrauterine contraceptive devices: randomized study. Am J Obstet Gynecol. 1996;175:1231-5.
Celen S, Möröy P, Sucak A, Aktulay A, Danisman N. Clinical outcomes of early postplacental insertion of intrauterine contraceptive devices. Contraception. 2004;69:279-82.
Araujo VB, Ortiz L, Smith J. Postpartum IUD in Paraguay: a case series of 3000 cases. Contraception. 2012;86:173-86.
Blumenthal P, Shiliya N, Neukom J, Chilambwe J, Vwalika B, Prager B, et al. Expulsion rates and satisfaction levels among immediate postpartum IUD users in peri-urban Lusaka, Zambia. Contraception. 2011;84:320.
Kittur S, Kabadi YM. Enhancing contraceptive usage by post-placental intrauterine contraceptive devices (PPIUCD) insertion with evaluation of safety, efficacy, and expulsion. Int J Reprod Contracept Obstet Gynecol. 2012;1:26-32.
Shukla M, Qureshi S, Chandrawati. Post-placental intrauterine device insertion - a five year expérience at a tertiary care centre in north India. Indian J Med Res. 2012;136:432-5.
Bonilla Rosales F, Aguilar Zamudio M, Cázares Montero ML, Hernández Ortiz ME, Luna Ruiz MA. Factors for expulsion of intrauterine device TCu380A applied immediately postpartum and after a delayed period. Rev Med Inst Mex Seguro Soc. 2005;43:5-10.
Celen S, Sucak A, Yildiz Y, Danisman N. Immediate post-placental insertion of an intrauterine contraceptive device during cesarean section. Contraception. 2011;84:240-3.
Roberts CL, Algert CS, Ford JB, Todd AL, Morris JM. Pathways to a rising caesarean section rate: a population-based cohort study. BMJ Open. 2012;2(5):e001725.
Somesh Kumar, Reena Sethi, Sudharsanam Balasubramaniam, Elaine Charurat, Kamlesh Lalchandani, Richard Semba, et al. Women’s experience with postpartum intrauterine contraceptive device use in India. Reprod Health. 2014;11:32.