Study on umbilical cord arterial blood gas analysis and cord blood lactate levels as predictors for adverse neonatal outcome: an observational study

Suman Shivanagouda Patil, Sukanya ., Suman Rath, Carolin Elizabeth George

Abstract


Background: Perinatal asphyxia is a major cause of neonatal and childhood morbidity and mortality. Electronic foetal monitoring is used routinely to know the condition of the baby during Intrapartum period. Normal trace correlates highly with absence of acidemia at birth. Abnormal trace needs further evaluation. In order to better define the metabolic status of the new born, umbilical lactate levels have been measured. Objectives of this study were to determine the validity of umbilical cord blood lactate levels in predicting the adverse early neonatal outcome in babies with intrapartum foetal distress and to compare the validity of umbilical cord blood lactate and umbilical artery pH in predicting adverse neonatal outcome in babies with intrapartum foetal distress.

Methods: 295 pregnant women with abnormal CTG in active labour were subjected for estimation of cord blood lactate and umbilical artery pH immediately after delivery and were compared in predicting adverse neonatal outcome.

Results: In the present study specificity of serum lactate (97.7%) and umbilical artery pH (95.97%) was almost similar in babies with Apgar <7 at 1 minute and 5 minutes, but sensitivity of serum lactate (23.14%) and cord ph (31.4%) was less in babies with Apgar score ≤7 at 1 minute. Area under ROC showed serum lactate is more accurate in predicting adverse neonatal outcome compared to umbilical artery pH.

Conclusions: Umbilical cord blood lactate is more specific than umbilical artery pH in predicting adverse neonatal outcome. Area under ROC (at 95th percentile) shown serum lactate is more accurate in predicting adverse neonatal outcome compared to umbilical artery pH at birth.


Keywords


Fetal distress, Hypertension in pregnancy, Stillbirths

Full Text:

PDF

References


Tasnim N, Mahmud G, Akram S. Predictive accuracy of intrapartum Cardiotocography in terms of fetal acid base status at birth. J Coll Physicians Surg Pak. 2009;19(10):632-5.

Malin GL, Morris RK, Kha KS. Strength of association between umbilical cord pH and perinatal and long-term outcomes: systematic review and meta-analysis. BMJ. 2010;340:c1471.

Parveen S. Umbilical cord arterial blood base excess as gold standard for foetal well-being screening test validity at term delivery. J PakMed Assoc. 2010;60(5):347-50.

Palomäki O, Luukkaala T, Luoto R, Tuimala R Intrapartum cardiotocography: the dilemma of interpretational variation. J Perinat Med. 2006:34(4):298-302.

Mires G, Williams F, Howie P. Randomized controlled trial of cardiotocography versus Doppler auscultation of fetal heart at admission in labour in low risk Obstetric population. BMJ. 2001;322(7300):1457-60.

Dellinger EH, Boehm FH, Crane MM. Electronic fetal heart rate monitoring: early neonatal outcomes associated with normal rate, fetal stress and fetal distress. Am J Obstet Gynecol. 2000;182(1)(1):214-20.

Borruto F, Comparetto C, Wegher E, Treisser A. Screening of foetal distress by assessment of umbilical cord lactate. Clin Exp Obstet Gynecol. 2006;33(4):219-22.

Johnson JW, Richards DS, Wagaman RA. The case for routine umbilical blood acid-base studies at delivery. Am J Obstet Gynecol. 1990;162(3):621-5.

Modarressnejad V. Umbilical cord blood pH and risk factors for acidaemia in Neonates in Kerman. East Mediterr Health J. 2005;11(1-2):96-101.

Sykes GS, Molloy PM, Johnson P, GuW, AshworthF, Stirrat GM, et al. Do Apgar scores indicate asphyxia? Lancet. 1982;1(8270):494-6.

What to Expect. Fetal distress during pregnancy. Available at http://www.whattoexpect.com/pregnancy/pregnancyhealth/complications/fetal-distress.aspx

Hamed HO. Intrapartum fetal asphyxia: study of umbilical cord blood lactate in relation to fetal heart rate patterns. Arch Gynecol Obstet. 2013;287(6):1067-73.

Damodaran GK. APGAR score and umbilical cord blood levels of lactate and creatinine in perinatal asphyxia. Int J Biomed Res. 2015;6(04):242-5.

Gjerris AC, Staer-Jensen J, Jørgensen JS, Bergholt T, Nickelsen C. Umbilical cord blood lactate: a valuable tool in the assessment of fetal metabolic acidosis. Eu J Obstet Gynecol Reprod Biol. 2008;129(1):16-20.

Shah S, Tracy M, Smyth J. Postnatal lactate as an early predictor of short-term out come after intrapartum asphyxia. J Perinatol. 2004;24(1):16-20.

Westgren M, Divon M, Horal M. Routine measurements of umbilical artery lactate levels in the prediction of perinatal outcome. Am J Obstet Gynecol. 1995;173(5):1416-22.

Wing FW, Kok HT, George SH. Umbilical cord lactate: a preliminary study of 130 term babies. Singapore J Obstet Gynaecol. 2002;33(2):42-8.