Comparative study of immediate post placental vaginal versus intra caesarean insertion of copper T380A

Authors

  • Rashmi Dhaduti Department of Obstetrics and Gynecology, Government Medical College and Hospital, Aurangabad, Maharashtra, India
  • Sonali Deshpande Department of Obstetrics and Gynecology, Government Medical College and Hospital, Aurangabad, Maharashtra, India
  • Shrinivas Gadappa Department of Obstetrics and Gynecology, Government Medical College and Hospital, Aurangabad, Maharashtra, India
  • Nutan Wanjare Department of Obstetrics and Gynecology, Government Medical College and Hospital, Aurangabad, Maharashtra, India
  • Sandeep Pund Department of Preventive and Social Medicine, Government Medical College and Hospital, Aurangabad, Maharashtra, India

DOI:

https://doi.org/10.18203/2320-1770.ijrcog20183309

Keywords:

PPIUCD, CopperT380A, Intracaesarean, Immediate postplacental vaginal IUCD

Abstract

Background: The study was carried out to compare modes of PPIUCD that is safety, removal and expulsion rates of immediate post placental vaginal versus intracaesarean insertion of copper T380A.

Methods: This was an interventional study conducted from January 2015 to December 2016 in Department of Obstetrics and Gynaecology, Government Medical College and Hospital, Aurangabad. This study involved participants who accepted PPIUCD in antenatal period and delivered in Government Medical College and Hospital, Aurangabad. Copper T380A was inserted vaginally after taking consent in 50 postpartum mothers within 10 minutes of normal vaginal delivery and 50 women who were undergoing caesarean section for obstetric indications who accepted copper T380A from contraceptive basket. Chorioamnionitis, prolonged premature rupture of membranes, unresolved postpartum hemorrhage, major medical disorder and participants who were lost to follow up were excluded. Antibiotic cover was given for 5 days. Participants were followed up either personally or telephonically at 6 weeks, 6 months or earlier if they had any complaints.

Results: Among 50 post placental vaginally copper T380A inserted participants, 6(12%) had menstrual disturbance and pain abdomen each. One participant (2%) had infection vaginitis. Among 50 intracaesarean copper T380A inserted participants, 3 (6%) had menstrual disturbance and pain abdomen each. 6 (12%) had missing strings. Missing strings which was seen only in intracaesarean group was statistically significant when compared to post placental vaginal group. Expulsion was seen only in post placental vaginally copper T380A inserted participants (4 out of 50). There was no statistically significant difference in expulsion & removal rates of both the groups.

Conclusions: Both modes of PPIUCD insertion were equally safe for participants except for missing strings which was seen more in intracaesarean group and was statistically significant.

References

Transforming our world: the 2030 Agenda for Sustainable Development" United Nations - Sustainable Development knowledge platform. Retrieved 23 August 2015. Available at: https://sustainabledevelopment.un.org/post2015/transformingourworld

Postpartum IUCD Reference Mannual, 2010, Family Planning Division, Ministry of Health and Family Welfare, Government of India.

Lopez LM, Bernholc A, Hubacher D, Stuart G, Van Vliet HA. Immediate postpartum insertion of intrauterine device for contraception. The Cochrane Library. 2015 Jan 1.

Singal S, Bharti R, Dewan R. Clinical outcome of postplacental Copper T 380A insertion in women delivering by caesarean section. J Clinical Diagnos Res: JCDR. 2014 Sep;8(9):OC01.

Hooda R, Mann S, Nanda S, Gupta A, More H, Bhutani J. Immediate postpartum intrauterine contraceptive device insertions in caesarean and vaginal deliveries: a comparative study of follow-up outcomes. Int J Reprod Med. 2016;2016.

Halder A, Sowmya MS, Gayen A, Bhattacharya P, Mukherjee S, Datta S. A prospective study to evaluate vaginal insertion and intra-cesarean insertion of post-partum intrauterine contraceptive device. The J Obstetr Gynecol India. 2016 Feb 1;66(1):35-41.

Rahaman M, Col. (Dr.) Sood AK, Col. (Dr.) Shrivastavan AK. Evaluation of spontaneous expulsion after immediate postpartum intrauterine contraceptive device (PPIUCDs) insertion. IOSR J Dental Med Sci (IOSR-JDMS). 2017;16(5):60-3.

Gupta D, Sharma S, Kanhere A, Jahan I. Study of acceptance of intra caesarean IUCD as a method of contraception. Int J Reprod Contracept Obstet Gynaecol. 2017;6:5033-7.

Sujananendra M. Evaluation of safety, efficacy and expulsion of postplacental and intracaesarean insertion of intrauterine contraceptive device (PPIUCD). J Obstet Gynaecol India. September-October 2014;64(5):337-43.

Gautam R, Arya KN, Kharakwal S, Singh S, Trivedi M. Overview of immediate PPIUCD application in Bundelkhand Region. J Evol Med Dent Sci. 2014 Aug 18;3(36):9518-26.

Garuda L, Kambham S, Neelohita B. Clinical Outcome of Ppiucd (Copper-380A)-Intracaesarean Insertion. Indian J Obstet Gynecol Res. 2015;2(4):218-26.

Downloads

Published

2018-07-26

Issue

Section

Original Research Articles